NV230 / NV400
The power distribution serves for the central power supply of consumers in the alternating current network.
It is intended to apply an alternating voltage to several output plug connections.
The outputs are individually fused via automatic circuit breakers and realized with cold-device plug connections.
NV400
The device is equipped with a two-circuit emergency stop system. For the connection of the consumers there are 13 IEC sockets, a Schuko socket, a Neutrik PowerCon socket (optional), all for 230 V, and a Winsta system socket for 400 V available.
Two versions of the NV400 are available:
The version 16A with a maximum input current of 3 x 16 A and the version 32A with a maximum input current of 3 x 32 A.
The power distribution NV400 can be used in a 19" vessel system or stand-alone as desktop unit.
NV230 | |
---|---|
Input voltage | 230 V - 240 V L1/N/PE |
Input current total | max. 16 A |
Frequency | 50/60 Hz |
Total power consumption | max. 3600 W |
Input line protection | 2-pole, 16 A, C-characteristics, automatic control unit |
Fi protection | 30 mA |
Output voltage | 200 V - 240 V L1/N/PE |
Output current per output | max. 10 A |
Line protection per output | 1-pole, 10 A, C-characteristic, automatic |
Operating temperature range | +5 °C to +70 °C |
Storage temperature range | -10 °C to +70 °C |
Air humidity | max. 80 % |
Altitude above sea level max. 2000 m | |
Dimensions (w x h x d) | 485 mm (19" installation) x 8 9mm x 340 mm |
weight | 7,5 kg |
Housing material | Aluminium anodized |
NV400 | Version 16A | Version 32A | |
---|---|---|---|
Input voltage | 360 V - 440 V L1/L2/L3/N/PE | 360 V - 440 V L1/L2/L3/N/PE | |
Input current total | max. 3 x 16 A | max. 3 x 32 A | |
Frequency | 50/60 Hz | 50/60 Hz | |
Total power consumption | max. 10.8 kW | max. 21.6 kW | |
Input line protection | 2-pole, 16 A, C-characteristic, automat | 3-pole, 32 A, C-characteristic, automat | |
Fi protection | 30 mA | 30 mA | |
Output voltage (230 V outputs) | 200 V - 240 V L1/N/PE L2/N/PE L3/N/PE | 200 V - 240 V L1/N/PE L2/N/PE L3/N/PE | |
Output current per output (230 V outputs) | max. 16 A | max. 16 A | |
Line protection (230V outputs) | 1-pole, 16 A, C-characteristic, automat | 1-pole, 16 A, C-characteristic, automat | |
Output voltage (400V output) | 360 V - 440 V L1/L2/L3/N/PE | 360 V - 440 V L1/L2/L3/N/PE | |
Output current (400V output) | 3 x 16 A | 3 x 25 A | |
Line protection (400 V output) | 3-pole, 16 A, C-characteristic, Automatic | 3-pole, 25A, C-characteristic, Automatic | |
Operating temperature range (400 V output) | +5 °C to +70 °C | +5 °C to +70 °C | |
Storage temperature range (400 V output) | -10 °C up to +70 °C | -10 °C up to +70 °C | |
Air humidity | max. 80 % | max. 80 % | max. |
Altitude above sea level max. 2000 m | max. 2000 m | ||
Dimensions (w x h x d) | 485 mm (19" installation) x 135 mm x 470 mm | 485 mm (19" installation) x 135 mm x 470 mm | |
Weight | 6.0 kg | 6.8 kg | |
Housing material | Anodised aluminium | Anodised aluminium | Anodised aluminium |